Decapping Low-Speed Centrifuge: Care and Storage When Idle for Long Periods

by Javenlab Engineering TeamMaintenanceDecappingLow-speed

The decapping low-speed centrifuge belongs to the low-speed centrifuge category (its maximum speed is usually within 4000 rpm and does not exceed 6000 rpm). Its decapping action relies on a specially structured recessed platform (the decapping basket/adapter): after a capped blood collection tube is placed in the platform, starting the machine generates centrifugal force that pushes the tube body downward, while the cap — having a larger diameter — is caught by the platform. The cap and tube body thus separate automatically, with no additional powered mechanism required throughout the process.

Key features of the instrument include:

  • Microcomputer control with presets for working programs, RCF, speed, and run time, all shown synchronously on the LED display.
  • Dual door lock system that locks as soon as the run starts, ensuring safe operation.
  • 20 selectable working programs; users can freely program and recall their set parameters, avoiding repeated setup and improving work efficiency.
  • RCF and speed are set and displayed synchronously.
  • Automatic balancing and imbalance protection, with an audible alert in case of error or imbalance; automatic imbalance detection and overspeed protection.

Routine Cleaning and Maintenance

  • Centrifuge chamber: after each use, first wipe away dust and debris with a dry cloth, then wipe the inner wall and bottom with a soft cloth moistened with 75% alcohol or a neutral detergent, and finally dry with a clean cloth. Pay special attention to the gaps between the rotor and the chamber to prevent residual samples from corroding the metal. If condensation forms during low-temperature use, open the lid and let the chamber air-dry naturally for 30 minutes.
  • Rotor and decapping adapters: remove them weekly for deep cleaning — soak in clean water or neutral detergent for 10–15 minutes, gently brush the surfaces and holes with a soft brush, rinse with distilled water, and invert to air-dry (use cold air only if blow-drying). Never use steel wool or strongly acidic/alkaline cleaners, which damage the rotor's protective layer; clean immediately after separating corrosive samples.
  • Outer surfaces and control panel: disinfect the exterior regularly with 75% alcohol; wipe the control panel with a slightly damp lint-free cloth, taking care that no liquid seeps in and damages the circuitry.

Fault Prevention and Long-Term Storage

  • Preventing faults in daily operation: strict balancing is mandatory (the weight difference between symmetrical tubes must not exceed 0.1 g); use the lowest speed that meets your separation needs to reduce the load on the motor bearings; always confirm the rotor is firmly secured before starting, and wait until the rotor is completely stationary before opening the lid — forcing the door open can damage the mechanism.
  • Environment control: place the equipment on a level surface in a dry, ventilated location, with ambient temperature controlled at 10–30°C and humidity below 80%, away from water sources, heat sources, and corrosive gases; clean the cooling fan filter monthly to prevent dust buildup from overheating the motor.
  • Long-term idle handling: if the machine will be idle for more than a month, clean and dry the rotor, remove it, and store it separately; place a desiccant bag inside the chamber, switch off the power, and cover the unit with a dust cover. Before putting it back into service, inspect the condition of all parts and run a power-on test to confirm everything works normally.
  • Record management: keep a maintenance log recording cleaning, inspections, part replacements, and abnormalities. Standardized records are the most effective way to guarantee stable long-term operation.

Recommended models

JW-1044R [Vertical] JW-1044R Touchscreen Low-speed Refrigerated Centrifuge (Vertical) — Jiavenlab laboratory centrifuge
JW-1044R [Vertical]Low-speed Refrigerated Centrifuge
JW-1044R Touchscreen Low-speed Refrigerated Centrifuge (Vertical)
  • Max Speed6000rpm
  • Max RCF5502xg
  • Capacity750mlx4
Contact for Price
JW-2002 JW-2002 Touchscreen Low-speed Centrifuge — Jiavenlab laboratory centrifuge
JW-2002Low-speed Centrifuge
JW-2002 Touchscreen Low-speed Centrifuge
  • Max Speed5000rpm
  • Max RCF3130xg
  • Capacity15mlx12
$1,190
JW-2032 JW-2032 Touchscreen Low-speed Centrifuge — Jiavenlab laboratory centrifuge
JW-2032Low-speed Centrifuge
JW-2032 Touchscreen Low-speed Centrifuge
  • Max Speed6000rpm
  • Max RCF5502xg
  • Capacity100mlx8
$898

Need help choosing a centrifuge?

Send us your protocol — engineers reply within 24 hours with a model recommendation.

Request a Quote
Decapping Centrifuge: Long-Term Storage Care | Jiavenlab Centrifuges